In the design of Switch-Box - System 5000 special emphasis was placed on the high availability of the complete clock system even during the presence of a fault.
The following aspects were taken into consideration for the different fault conditions:
Signal output even in the case of Switch-Box voltage failure by means of signal switchover via relay (signal output always from the Master System in this case)
Error message from the Switch-Box via relay and LEDs in the event of faulty transmission of status signals to the Switch-Box (e.g. broken cable)
Error message from the Switch-Box via relay and LEDs followed by switchover or further output of the Master System's signals in the event of the transmission of ambiguous status signals to the Switch-Box
Error message of the Switch-Box via relay and LEDs in the event of the total failure of the Master or Redundant System
Error message of the Switch-Box in the event of power supply failure
Error message of the Switch-Box via relay in the event of failure of Control Board 5100
Manual configuration of signal outputs to the Master or Redundant System is possible (not in the event of power failure)
In case of doubt the Master System's signals are always transmitted
Base system in 1/1 19" rack (3U/84HP) including Control Board 5100 and power supply unit
Power supply 115/230V AC - other voltages possible
Intelligent signal switchover dependent on the operating conditions of the Master and Redundant systems
Free assignment of error priority in the hopf System 7001 and 7001RC
Error and status reporting incorporated into Switch-Box for switchover availability over relay (dry contact) and LEDs
All Switch-Boards are hot-plug compatible
System completely maintenance-free
All cable connections on the rear
Status LEDs on both front and rear
Casing with additional ground screw for cables up to 16mm²
Incoming voltage feed with mains switch in accordance with IEC/EN 60320-1/C14 and EMI line interference suppression filter
Prepared for customer retrofitting of Switch-Boards
No additional blanking panels required on system expansion
Casing extension with additional Switch-Board slots possible for larger systems
Switchover mode for each Switch-Board adjustable via switch on the board faceplate (output fixed to Redundant System / output fixed to Master System / output controlled by Switch-Box)
Complete electrical isolation of the Master and Redundant clock system output signals
Easy expansion of existing stand-alone systems to a redundant system with 'hot standby function with automatic status-dependent signal switchover to redundant system'
Parameterizable Switchover function: Switchover only by major error or Switchover by major and / or minor error
Expansion Options
Customer-specific system adaptations for 'tailor-made' project solutions